+.SH "MACRO MAGIC"
+.IX Header "MACRO MAGIC"
+Libev can be compiled with a variety of options, the most fundemantal is
+\&\f(CW\*(C`EV_MULTIPLICITY\*(C'\fR. This option determines whether (most) functions and
+callbacks have an initial \f(CW\*(C`struct ev_loop *\*(C'\fR argument.
+.PP
+To make it easier to write programs that cope with either variant, the
+following macros are defined:
+.ie n .IP """EV_A""\fR, \f(CW""EV_A_""" 4
+.el .IP "\f(CWEV_A\fR, \f(CWEV_A_\fR" 4
+.IX Item "EV_A, EV_A_"
+This provides the loop \fIargument\fR for functions, if one is required (\*(L"ev
+loop argument\*(R"). The \f(CW\*(C`EV_A\*(C'\fR form is used when this is the sole argument,
+\&\f(CW\*(C`EV_A_\*(C'\fR is used when other arguments are following. Example:
+.Sp
+.Vb 3
+\& ev_unref (EV_A);
+\& ev_timer_add (EV_A_ watcher);
+\& ev_loop (EV_A_ 0);
+.Ve
+.Sp
+It assumes the variable \f(CW\*(C`loop\*(C'\fR of type \f(CW\*(C`struct ev_loop *\*(C'\fR is in scope,
+which is often provided by the following macro.
+.ie n .IP """EV_P""\fR, \f(CW""EV_P_""" 4
+.el .IP "\f(CWEV_P\fR, \f(CWEV_P_\fR" 4
+.IX Item "EV_P, EV_P_"
+This provides the loop \fIparameter\fR for functions, if one is required (\*(L"ev
+loop parameter\*(R"). The \f(CW\*(C`EV_P\*(C'\fR form is used when this is the sole parameter,
+\&\f(CW\*(C`EV_P_\*(C'\fR is used when other parameters are following. Example:
+.Sp
+.Vb 2
+\& // this is how ev_unref is being declared
+\& static void ev_unref (EV_P);
+.Ve
+.Sp
+.Vb 2
+\& // this is how you can declare your typical callback
+\& static void cb (EV_P_ ev_timer *w, int revents)
+.Ve
+.Sp
+It declares a parameter \f(CW\*(C`loop\*(C'\fR of type \f(CW\*(C`struct ev_loop *\*(C'\fR, quite
+suitable for use with \f(CW\*(C`EV_A\*(C'\fR.
+.ie n .IP """EV_DEFAULT""\fR, \f(CW""EV_DEFAULT_""" 4
+.el .IP "\f(CWEV_DEFAULT\fR, \f(CWEV_DEFAULT_\fR" 4
+.IX Item "EV_DEFAULT, EV_DEFAULT_"
+Similar to the other two macros, this gives you the value of the default
+loop, if multiple loops are supported (\*(L"ev loop default\*(R").
+.PP
+Example: Declare and initialise a check watcher, utilising the above
+macros so it will work regardless of whether multiple loops are supported
+or not.
+.PP
+.Vb 5
+\& static void
+\& check_cb (EV_P_ ev_timer *w, int revents)
+\& {
+\& ev_check_stop (EV_A_ w);
+\& }
+.Ve
+.PP
+.Vb 4
+\& ev_check check;
+\& ev_check_init (&check, check_cb);
+\& ev_check_start (EV_DEFAULT_ &check);
+\& ev_loop (EV_DEFAULT_ 0);
+.Ve